48596CONTROL PANEL AD9
AD961-945NI
LMI Metering Pump - 2.0 GPH - 50 psi - PP
AD Series·Back to the AD96 selector
- Maximum flow
- 2 GPH
- Minimum flow
- 0.02 GPH
- Maximum pressure
- 50 psi
- Head material
- Polypropylene
- Seals
- Teflon
- Fittings
- Polypropylene
- Check-valve balls
- Ceramic
- Tubing
- Low Density Polyethylene
Need help with this product? Call FSC (941) 426-9872
Overview
The LMI AD961-945NI is an Excel AD solenoid-driven diaphragm metering pump with a polypropylene FastPrime liquid end, rated up to 2 GPH and up to 50 psi. It includes a pulse or 4–20 mA input plus 4–20 mA, pulse, and alarm outputs for remote control and monitoring.
Check it with FSC before you order
Send your chemical, concentration and operating conditions, and FSC will confirm this is the right fit.
Specifications
- Maximum flow
- 2 GPH
- Minimum flow
- 0.02 GPH
- Maximum pressure
- 50 psi
- Head material
- Polypropylene
- Seals
- Teflon
- Fittings
- Polypropylene
- Check-valve balls
- Ceramic
- Tubing
- Low Density Polyethylene
- Control
- Stroke Length Control, Manual | Stroke Frequency (Speed) Control, Digital | Pulse Control, Analog | 4-20mA Control
- Power supply
- Universal or Dual 115/230V
- Stroke rate
- 120 SPM
- Stroke volume
- 1.05 ml
- Turndown
- 1000:1
- Suction lift
- 5 ft
- Accuracy
- 2%
- Power input
- 20 W
- Connections
- 3/8" OD PE
- Power connection
- US 115V - NEMA 5/15 - Type B
- Certifications
- CE, NSF 61, NSF 50, UL, CUL
Selected options
- Connections
- Inch Tubing
- Control option
- Pulse Input/Output - 4-20mA Input/Output - Dual Manual Control
- Power cord
- 115V - USA
- Liquid end type
- FastPrime Machined
- Accessory valve
- Not Included
- Liquid end materials
- PP w/ PTFE Seals
- Diaphragm size
- Size Code 4 Liquifram
Spare parts for AD961-945NI
Listed for this model or its liquid end.